Ultraprobe® 201 Grease Caddy Technical Specifications

Housing: Attaches directly to the grease gun, gives visual & audible indication for proper lubrication.

Construction: Aluminum

Dimensions: 5.25″ x 2.65″ x 1.25″ (13.3 x 6.7 x 4.5 cm) (LWH)

Operating Temperature (GCUPU): 32°F-140°F (0°- 60°C)

Relative Humidity: 10-95% non-condensing at up to 86°F (30°C)

Circuitry: SMD/Solid State heterodyne receiver

Transducer: Piezoelectric (Acoustically isolated from Grease Gun)

Frequency Response: Peak response: centered around 38 kHz

Indicator: 10 Segment LED Bar Graph (red)

Sensitivity Selection: 8 position precision attenuation

Power: Rechargeable nickel metal hydride

Power off: Time delay

Low Battery Indicator: LED

Headset: Weight: 2.5 Oz.

Operating Temp. Range (Transducer): 14°F to 167°F (-10° to 75°C)

Cable: 48″ shielded.

Deluxe noise isolating headset for hardhat use. Over 23 dB of noise attenuation. Meets or exceeds ANSI Specifications, & OSHA standards.

Attachment: Universal: fits most commercially used cartridge grease guns.

Weight: 16 oz (.45 kg)

Warranty: 1 year parts/labor standard.